INPUT SPEC
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY: 47 ~ 63 HZ
INPUT CURRENT: 9A(RMS) FOR 115VAC, 4.5A(RMS) FOR 230 VAC
INRUSH CURRENT: 50A MAX. FOR 115 VAC, 100A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET
OF 95% AT 115/230VAC, FULL LOAD
FEATURES
‧TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
‧HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
‧EFFICIENCY: 87~90% TYPICAL AT 115V, FULL LOAD
‧LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE VAC
‧POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
‧OVER POWER PROTECTION: 110~160%
‧OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V
‧OVER CURRENT PROTECTOIN: +3.3V→27.5~40A, +5V→27.5~40A, +12V→52.8~72.8A
‧SHORT CIRCUIT PROTECTION
‧EMI: FCC CLASS B, CISPR22 CLASS B
‧SAFETY: TO MEET UL, CUL, TÜV, CCC
‧COOLING: ONE 60mm DC FAN
‧MEET IEC-1000-3-2 CLASS D
Shipping Information
| QLD | From $9.95 | Free over $200 | 1-3 business days |
| NSW / VIC / ACT | From $12.95 | Free over $300 | 3-5 business days |
| SA / TAS | From $14.95 | Free over $300 | 4-6 business days |
| WA / NT | From $19.95 | Free over $500 | 5-8 business days |
Product weight: 0.20 kg